Navigating Between Controllers Using the Zapi Standard Console
Getting Started
- Connect the console to the serial port on your ACE2 Inverter
- Power on the truck
What you'll see on startup
When you first turn on the console, it will display two startup screens:
First Screen:
ZAPI
CONSOLE V x.x
This shows your console software version.
Second Screen:
CONNECTED TO
AE2P2B H NRx.xx
48 V 500A XXXXX
This displays information about the controller you're connected to.
If no alarms are active, you'll proceed to the main screen.
How to switch between controllers (Nodes)
Step 1: Enter The Configuration Menu
- Press the Top Left and Top Right buttons simultaneously
- You'll see: CONFIG MENU
Step 2: Access Set Model
- Press ENTER to select SET MODEL
- The screen will show which node you're currently connected to: CONNECTED TO 5
Step 3: Select Your Desired Node
Use buttons 5 and 6 to scroll through available nodes:
Node Number | Controller Type |
---|---|
Node 2 | Traction |
Node 5 | Pump |
Node 6 | Steer |
Step 4: Confirm Your Selection
- Once you've highlighted the node you want, press OUT
- You'll see a confirmation prompt:
ARE YOU SURE?
YES=ENTER NO=OUT
- Press Enter to confirm or OUT to cancel.
Step 5: Exit Configuration
- The screen returns to SET MODEL
- Press OUT again to exit the configuration menu.
Step 6: You're Connected
- The console will now display the selected controllers information:
A3MT2C 2NNR x.xx 48V 600A xxxxx
You can now navigate the menus for your selected controller (e.g., ACE3 Traction Inverter).
Quick Reference
- Entering Config Menu: Top Left + Top Right buttons
- Scrolling Nodes: Buttons 5 & 6
- Confirming Selection: ENTER
- Going Back: OUT
Troubleshooting Tips
- If you don't see the startup screens, check your serial connection
- If an alarm is present, it may need to be cleared before accessing the configuration menu
- Always confirm you're on the correct node before making any changes