Controller Node ID Information
ACiON GEN2
PC CAN Console / Smart Console – Connection
When connecting, select:
DEVICE PROTOCOL = CAN OPEN
Controller Node IDs
Traction
Master
NODE 8
A2MT2C
SW NR0.31
Supervisor
NODE 9
A2ST2C
SW NR0.31
Pump
Master
NODE 16
A2MP2B
SW NR0.31
Supervisor
NODE 17
A2SP2B
SW NR0.31
Steer
Master
NODE 24
AXMT2B
SW NR0.31
Supervisor
NODE 25
AXST2B
SW NR0.31
Display
Master Processor
NODE 16
Connecting to Display
Select in PC CAN Console or Smart Console:
DEVICE PROTOCOL = STANDARD
· FORCE REMOTE PROTOCOL = TICKED
Important – Master Node Only
All parameter changes are to be made in the Master Processor Node only. No changes can be made in Supervisor Nodes.
Eco Smart Display – Alarm Visualisation
Alarms are displayed in the format: Axxx ON [SYSTEM]
Traction
Axxx ON TRACTION
Alarm on Master Processor
Axxx ON NODE 34
Alarm on Supervisor Processor
Pump
Axxx ON PUMP
Alarm on Master Processor
Axxx ON NODE 36
Alarm on Supervisor Processor
Steer
Axxx ON STEER
Alarm on Master Processor
Axxx ON NODE 38
Alarm on Supervisor Processor
Display
Axxx ON DISPLAY
Alarm on Master Processor
Flexi – Service Engineering Reference