ACiON GEN2 – Controller Node ID Information

Controller Node ID Information

ACiON GEN2
PC CAN Console / Smart Console – Connection
When connecting, select: DEVICE PROTOCOL = CAN OPEN
Controller Node IDs
Traction
Master NODE 8 A2MT2C SW NR0.31
Supervisor NODE 9 A2ST2C SW NR0.31
Pump
Master NODE 16 A2MP2B SW NR0.31
Supervisor NODE 17 A2SP2B SW NR0.31
Steer
Master NODE 24 AXMT2B SW NR0.31
Supervisor NODE 25 AXST2B SW NR0.31
Display
Master Processor NODE 16
Connecting to Display
Select in PC CAN Console or Smart Console:
DEVICE PROTOCOL = STANDARD  ·  FORCE REMOTE PROTOCOL = TICKED
Important – Master Node Only
All parameter changes are to be made in the Master Processor Node only. No changes can be made in Supervisor Nodes.
Eco Smart Display – Alarm Visualisation
Alarms are displayed in the format: Axxx ON [SYSTEM]
Traction
Axxx ON TRACTION Alarm on Master Processor
Axxx ON NODE 34 Alarm on Supervisor Processor
Pump
Axxx ON PUMP Alarm on Master Processor
Axxx ON NODE 36 Alarm on Supervisor Processor
Steer
Axxx ON STEER Alarm on Master Processor
Axxx ON NODE 38 Alarm on Supervisor Processor
Display
Axxx ON DISPLAY Alarm on Master Processor