Smart Stop
Minimum Software Level Reference
Minimum software versions and parameter settings required for Smart Stop function on Flexi ACe trucks.
ACE-3
Traction
nnr0.32
Minimum software version required
ACE-2
Pump
nnr0.32
Minimum software version required
AC-0
Steer
nnr0.32
Minimum software version required
ACE-2 Traction - Set Options
Parameters Required
| Menu | Parameter | Value |
|---|---|---|
| Set Options | SMART STOP SPD | 0.15 |
| Set Options | SMART STOP | ON |
ACE-2 Pump - Set Options
Parameters Required
| Menu | Parameter | Value |
|---|---|---|
| Set Options | EV3 | DIGITAL |
ACE-2 Pump - Tester Menu
Assignments
| Input / Output | Assignment |
|---|---|
| Pot #4 | Input S/Stop Right |
| Pot #2 | Input S/Stop Left |
| Output EV3 | Output Buzzer Relay |
Eco Display
Eco Display minimum software version is nnr0.17. This is separate from the inverter software versions listed above.
Important
All three inverters (Traction, Pump, Steer) must meet the minimum software level before Smart Stop can function correctly.