Smart Stop - Minimum Software Level
Flexi

Smart Stop

Minimum Software Level Reference

ACE-3
Traction
nnr0.32
Minimum software version required
ACE-2
Pump
nnr0.32
Minimum software version required
AC-0
Steer
nnr0.32
Minimum software version required
ACE-2 Traction - Set Options Parameters Required
Menu Parameter Value
Set Options SMART STOP SPD 0.15
Set Options SMART STOP ON
ACE-2 Pump - Set Options Parameters Required
Menu Parameter Value
Set Options EV3 DIGITAL
ACE-2 Pump - Tester Menu Assignments
Input / Output Assignment
Pot #4 Input S/Stop Right
Pot #2 Input S/Stop Left
Output EV3 Output Buzzer Relay
Eco Display

Eco Display minimum software version is nnr0.17. This is separate from the inverter software versions listed above.

Important

All three inverters (Traction, Pump, Steer) must meet the minimum software level before Smart Stop can function correctly.