Program Lift/Lower Lever VACC
Flexi ACiON · Eco Smart Display
Prerequisite
Connect to the
Pump Inverter
before beginning this procedure.Phase 1 · Access the Controller
1
Press Key 3 (Enter)
twice to access the Password Screen.
ENTER PASSWORD
2
Enter your password using Keys 1 – 5.
ENTER PASSWORD · 152_
3
Use Key 1
to scroll to ZAPI CONSOLE
then press Enter (Key 3).
ZAPI CONSOLE
4
Use Key 1
to scroll until you see the CONNECTED TO
screen showing the Pump controller, then press Enter (Key 3). Pump
CONNECTED TO: A2MP2B 3NNR0.22
5
Press Key 3
to enter the Main Menu.
A2MP2B 3NNA0.22 · 48V 550A 00001
Phase 2 · Navigate to Program VACC
6
Use Key 1
to scroll through the Main Menu until PROGRAMM VACC
is visible.
★ MAIN MENU ★ · PARAMETER CHANGE
7
Scroll to PROGRAMM VACC
and press Enter (Key 3).
★ MAIN MENU ★ · PROGRAMM VACC
8
The display shows the current programmed VACC values. Press Enter (Key 3)
to start programming — both Min
and Max
values will reset to 0.0.
VACC SETTINGS · PROGRAM VACC · 0.0 5.0
Phase 3 · Teach Lower & Lift Positions Differs from Traction
9
Push the lift lever to the full lower position. You will see the MAX value change
as you do this. Lower first
10
Release the lever back to neutral
— the MAX value will return to 0.0. This is normal.
VACC SETTINGS · MIN VACC MAX · 0.0 0.0
11
Repeat the same process for the full lift position
— move lever to full lift, then release to neutral. Lift second
Phase 4 · Save & Complete
12
Once both positions are taught, press Out (Key 2)
to exit.
VACC SETTINGS · MIN VACC MAX · 0.0 0.0
13
The display will show ARE YOU SURE?
— press Enter (Key 3)
to save the changes.
ARE YOU SURE? · YES=ENTER NO=OUT
Key Differences vs. Traction VACC Procedure
Traction VACC (Node 8)
Connect to ACE2 Traction Inverter
CONNECTED TO: A2MT2C
Select Fwd direction → push pedal to floor
Repeat for Rev direction
Lift/Lower VACC (Node 16) ← This guide
Connect to Pump Inverter
CONNECTED TO: A2MP2B
Push lift lever to full Lower
→ release to neutral
Repeat for full Lift
position
Both positions must be taught.
The teaching procedure must be completed for the full lower
and full lift
positions separately. Skipping either will result in an incomplete calibration.
✓
Procedure Complete
Cycle the key to apply the saved Lift/Lower VACC settings.
Flexi – Service Engineering Reference