Flexi ACiON – Program Traction VACC

Program Traction VACC

Flexi ACiON · Eco Smart Display
Prerequisite
Connect to the Traction ACE2 Inverter before beginning this procedure.
Phase 1 · Access the Controller
1
Press Key 3 (Enter) twice to access the Password Screen.
ENTER PASSWORD
2
Enter your password using Keys 1 – 5.
ENTER PASSWORD · 152_
3
Use Key 1 to scroll to ZAPI CONSOLE then press Enter (Key 3).
ZAPI CONSOLE
4
Use Key 1 to scroll until you see the CONNECTED TO screen showing the Traction controller, then press Enter (Key 3).
CONNECTED TO: A2MT2C 3NNR0.22
5
Press Key 3 to enter the Main Menu.
A2MT2C 3NNA0.22 · 48V 550A 00001
Phase 2 · Navigate to Program VACC
6
Use Key 1 to scroll through the Main Menu until PROGRAMM VACC is visible.
★ MAIN MENU ★ · PARAMETER CHANGE
7
Scroll to PROGRAMM VACC and press Enter (Key 3).
★ MAIN MENU ★ · PROGRAMM VACC
8
The display shows the current programmed VACC values. Press Enter (Key 3) to start programming — both Min and Max values will reset to 0.0.
VACC SETTINGS · PROGRAM VACC · 0.0   5.0
Phase 3 · Teach Forward & Reverse
9
Select Forward direction and push the pedal fully to the floor. You will see the MAX value change as you do this.
10
Release the pedal — the MAX value will return to 0.0. This is normal.
VACC SETTINGS · MIN VACC MAX · 0.0   0.0
11
Repeat the same process for the Reverse direction — select Reverse, depress pedal fully, then release.
Phase 4 · Save & Complete
12
Once both directions are taught, press Out (Key 2) to exit.
VACC SETTINGS · MIN VACC MAX · 0.0   0.0
13
The display will show ARE YOU SURE? — press Enter (Key 3) to save the changes.
ARE YOU SURE? · YES=ENTER   NO=OUT
Both directions must be taught. The teaching procedure must be completed for Forward and Reverse separately. Skipping either direction will result in an incomplete calibration.
Procedure Complete
Cycle the key to apply the saved VACC settings.